How can we help?
Help center.
Short answers here. Detailed articles with screenshots are in the help center inside the app.
Getting started
What EMS is and how it works
An energy management system is the controller that decides, every few seconds, how much the battery charges or discharges, how much solar power is allowed and how much is bought or sold. It reads the meters, inverters and battery cabinets on site and keeps every limit you set. The app shows what it does and lets you change settings; the control itself runs on the controller.
Installing the app on a phone and a computer
Open starkonex.cloud in a browser and sign in. To install it as an app, choose Add to Home Screen on a phone, or the install icon in the address bar in Chrome or Edge on a computer. Notifications work once you allow them.
Signing in, password and regaining access
Sign in with the email address you were invited with. If you forgot the password, choose Forgot password on the sign-in page and follow the link in the email. If you no longer have access to that email, ask the administrator of your company account or write to support.
First setup of a station
A station is set up with the setup wizard: the address, the connection point limits, then each device by model and network address. The wizard checks that every device answers before control is switched on. Installers do this on site or remotely together with our support.
Station dashboard: energy flow, balance, charts
The energy flow shows live power between the grid, solar, the battery and the site. The balance shows energy for the day, and the charts show any measured value over time. An empty field means there is no reading right now: the app never fills gaps with estimates.
Control and modes
Control strategies: maximum revenue, self-consumption, by schedule
Maximum revenue charges when energy is cheap and discharges when it is expensive, using day-ahead prices. Self-consumption stores surplus solar and covers the site’s own load. By schedule follows a table of time windows you set. Several functions can work together, each with its own priority.
Day plan: the charge and discharge table
The day plan is a table of time windows. For each window you set the charge or discharge power, or a target state of charge. The limits of the connection point and of the battery always take precedence over the table.
Connection point limits per grid connection
For each grid connection you set the maximum power to buy and to sell, and whether selling is allowed at all. The controller keeps these limits on every cycle, also when another function asks for more.
How the battery is split: reserve, own use, arbitrage
Part of the capacity can be held as a reserve for a blackout, part used for the site’s own needs and the rest for trading on prices. The bar on the station page shows how the battery is divided right now.
Why the battery is not doing what I expect
Usually a limit takes priority: the connection point limit, the reserve, the battery’s own limits or reduced power because of temperature. The station page shows which function is in control. If it still looks wrong, open a support ticket from the station.
Market and money
What the price of a kWh is made up of
The final price is the day-ahead market price plus transmission, distribution and other charges and VAT, as set in the station’s tariff. The app shows each part separately.
Revenue today: how it is calculated
Revenue is calculated for each hour from the energy measured at the connection point and the price for that hour. Energy that was not measured is not counted.
Plan and fact: why expected revenue differs
The plan is made in advance from price and load forecasts. The fact depends on what really happened that day: the load, the sun and the limits. The app shows both, so you can see where the difference came from.
Why selling to the grid is cheaper than buying
When you sell, you usually receive only the market price, while buying adds transmission and distribution charges and taxes. That is why using your own solar is often worth more than selling it.
Reports: CSV and PDF
Any period can be exported as CSV for your own analysis or as a PDF report. Reports use the same measured data as the charts.
Reliability
Island: what happens when the grid goes down
On a site built for island operation, the battery cabinets take over when the grid goes down, within the limits of their power. When the grid returns, the site switches back. Which loads stay on depends on how the site is wired.
What the system does when the connection is lost
Control runs on the controller, so the site keeps working without internet. The app shows the last known data and marks it as not current. When the connection returns, the app shows live data again.
Safety limits that always apply
The connection point limits, the battery limits and the emergency stop input are kept by the controller itself. They do not depend on the cloud, the internet or the app.
Controller without internet: signing in on site
On site you can connect to the controller directly and open the same app locally. The access details are on the sheet that comes with the controller.
Auto-return after a controller restart
After a restart the controller loads its settings and resumes control on its own. Devices that are not answering yet are shown as not responding until they are back.
Alarms
Smoke detected in the cabinet: what to do
Keep the cabinet closed, keep people away and call the fire service if you see smoke or fire. Follow the site emergency instructions. Do not reset the alarm until a qualified person has checked the cause.
Battery overheating: what to do
The cabinet reduces power or stops by itself. Check that the ventilation or air conditioning works and that nothing blocks the air flow. If the alarm comes back, contact your installer or support.
Fire lockout and how it is cleared
After a fire alarm the cabinet stays locked and does not start. The lockout is cleared only after the cause has been inspected on site by a qualified person.
BMS disconnected
The controller has lost contact with the battery management system and stops using that cabinet. Check the communication cable and the cabinet’s power supply. Control resumes when the BMS answers again.
PCS disconnected
The controller has lost contact with the power conversion system and stops using that cabinet. Check the network cable and the power supply of the PCS. Control resumes when it answers again.
Account and access
Roles and access: what each user can do
Owners and administrators manage the station and its users, technicians commission devices, and viewers can only look. Every action in the app checks the role of the person doing it.
Access for other people
An administrator invites a person by email and chooses their role. Access can be changed or withdrawn at any moment.
Cloud subscription: state and renewal
Remote access through the cloud is paid per station. The subscription page shows its state and end date. Without an active subscription the site keeps working; only remote access is closed.
Station event log
Every alarm, command and change of settings is written to the station log with the time and the person who made it.
Support tickets: how to write one
Open a ticket from the station page and describe what you see and when it started. The ticket already includes the station and its recent log, so you do not need to explain the setup.
Open the full help center at starkonex.cloud
Nothing found. Try another word, or ask support.
Supported equipment.
136 device models and families. Search by brand or model, or pick a type.
Battery systems
- ADS-TEC StoraXeMonitoring
- Bosch BPT-S 5 Hybrid ESSMonitoring
- Deye SUN-10K-SG04LP3Control
- GoodWe ESSControl
- Gotion ESC-R125-261-CEControl
- KOSTAL PIKO 10–20Monitoring
- KOSTAL PIKO ESSMonitoring
- KOSTAL Plenticore ESSControl
- Samsung ESSMonitoring
- SMA Sunny Boy Storage 2.5Control
- SMA Sunny Island 4.4M/6.0H/8.0HControl
- SolarEdge ESSControl
- Victron Multiplus 2 ESSControl
Batteries
- BMW Battery-Rack BCSMonitoring
- BYD Battery-Box Commercial C130Monitoring
- Fronius Gen24 BatteryMonitoring
- Pylontech Powercube M2Monitoring
- SMA Sunny Tripower SE BatteryMonitoring
- Soltaro BMS Single Rack Version AMonitoring
- Soltaro BMS Single Rack Version BMonitoring
- Soltaro BMS Single Rack Version CMonitoring
- Soltaro Battery Cluster Version BControl
- Soltaro Battery Cluster Version CControl
- Tesla Powerwall 2Monitoring
- Victron CANBus BatteryMonitoring
PCS and battery inverters
- Fronius Gen24 Hybrid Battery-InverterControl
- GoodWe Battery-InverterControl
- KACO blueplanet gridsave PCSControl
- REFU 88K Battery-InverterControl
- REFU Battery-InverterControl
- Sinexcel Battery-InverterControl
- SMA Sunny Tripower SE Hybrid Battery-InverterControl
- Victron Battery-Inverter ROControl
Solar inverters
- Fronius Gen24Monitoring
- Fronius Gen24, Symo, Primo and other SunSpec modelsControl
- Fronius Symo/Primo PV-InverterMonitoring
- GoodWe ET, BT, EH seriesMonitoring
- GoodWe string invertersMonitoring
- Huawei SUN2000Control
- Huawei SUN2000 via SmartLoggerControl
- KACO blueplanetControl
- KACO blueplanet hybrid 10.0 TL3Control
- KOSTAL PIKOMonitoring
- KOSTAL PlenticoreControl
- KOSTAL Plenticore hybrid 10–20Monitoring
- KOSTAL Smart Energy Meter (KSEM) / PV-Inverter PlenticoreMonitoring
- OpenDTU Hoymiles, APsystems, TSUN microinvertersMonitoring
- Samsung ESS Charger / Grid-MeterMonitoring
- SMA Sunny TripowerMonitoring
- Solar-Log gatewayControl
- SolarEdge Inverters with SunSpec / Modbus TCPControl
- SolarEdge PV-Inverter / MeterMonitoring
- SolaX X3-FTH-125KControl
- Solis MB-S4-W4Control
- Solis S5-GC30KControl
- SunSpec Any inverter with SunSpec ModbusMonitoring
- Victron AC PV invertersMonitoring
- Victron BlueSolar / SmartSolar MPPTMonitoring
Meters
- ABB B23Monitoring
- Artemes AM-2Monitoring
- B+G E-Tech DRT428M-2Monitoring
- B-Control / TQ-Systems EM300Monitoring
- Camille Bauer APLUSMonitoring
- Carlo Gavazzi EM100Monitoring
- Carlo Gavazzi EM300 / EM330 / EM340Monitoring
- Chint DDSU666Monitoring
- Chint DTSU666Monitoring
- Discovergy Smart MeterMonitoring
- Eastron SDM120Monitoring
- Eastron SDM630 / SDM72D-M-2Monitoring
- Fronius SmartMeter (63A-3, TS 65A-3)Monitoring
- GoodWe STS Box / Genset / EmergencyPowerMeterMonitoring
- Hager ECR380DMonitoring
- Janitza UMG 104Monitoring
- Janitza UMG 511Monitoring
- Janitza UMG 604Monitoring
- Janitza UMG 801Monitoring
- Janitza UMG 806Monitoring
- Janitza UMG 808Monitoring
- Janitza UMG 96-PQ-LMonitoring
- Janitza UMG 96-RM-EMonitoring
- KDK 420506PRO20-U (2PU CT)Monitoring
- Phoenix Contact EEM-MB370-24DCMonitoring
- Plexlog DataloggerMonitoring
- PQ-Plus UMD 96Monitoring
- PQ-Plus UMD 97Monitoring
- Schneider Electric Acti9 SmartlinkMonitoring
- Shelly 3EMMonitoring
- Shelly 3EM Gen3Monitoring
- Shelly Pro 3EMMonitoring
- Siemens PAC1600Monitoring
- Siemens PAC2200 / PAC3200 / PAC4200Monitoring
- Siemens SICAM T7KG966Monitoring
- SMA Sunny Home Manager 2.0Monitoring
- Socomec Countis E14Monitoring
- Socomec Countis E23/E24/E27/E28/E34/E44/E47/E48, Diris A10/A14/B30Monitoring
- Weidmueller 525Monitoring
- Ziehl EFR4001IPMonitoring
EV chargers
- OCPP 1.6J any compatible chargerControl
- ABL Single eM4 (Controller/Extender)Monitoring
- Alpitronic HyperchargerControl
- Bender CC612 and Bender-based EVSE controllersMonitoring
- go-e Charger HomeControl
- go-e Gemini (HTTP API v2)Monitoring
- go-e Gemini (Modbus)Monitoring
- Hardy Barth cPH2 / SaliaControl
- Heidelberg Energy ControlControl
- Heidelberg Energy Control ConnectControl
- IES KeyWatt (Single CCS, DC)Control
- KEBA KeContact P30Control
- KEBA KeContact P40Control
- MENNEKES Amtron Professional / CompactControl
- OpenWB Series 2Monitoring
- Spelsberg SMARTControl
- Webasto NextControl
- Webasto UniteControl
Heat and loads
- Askoma Askoheat+Control
- my-PV AC-THOR 9sControl
- my-PV Heat my-PVControl
- Tele Haase NA003.COM-M64Monitoring
Relays and I/O
- F&F MR-AO-1Control
- KMtronic 4-Port Relay BoardControl
- KMtronic 8-Port Relay BoardControl
- Shelly 1Control
- Shelly 2.5Control
- Shelly Outdoor Plug S (Gen3)Control
- Shelly PlugControl
- Shelly Plug S (Gen3)Control
- Shelly Plus 1PMControl
- Shelly Plus PM MiniMonitoring
- Shelly Plus Plug SControl
- Shelly Pro 1PMControl
- Shelly Pro 2PM (Device + Terminal)Control
- Shelly Pro 3Control
- Shelly Pro 4PM (Device + Terminal)Control
Gateways
- Papouch TCP2RTU gatewayControl
This model is not on the list yet. Send us the model and we will check it.
Control the EMS reads the device and sends it setpoints. Monitoring the EMS reads values and alarms.
Not on the list? We add it.
Send us the model and its protocol documentation. A new driver is delivered to the controller without stopping the site.
Protocols
Modbus TCP, Modbus RTU over RS-485 and gateways. Each device class follows one standard, so cards, alarms and reports look the same for every brand.
Downloads.
No document in this language yet. Choose another language, or ask us.
Report a fault.
A cabinet alarm, a device that stopped answering or a site that does not behave as expected. Every request gets a number and goes straight to the service team.
Before you write
- If you see smoke or fire, keep the cabinet closed, keep people away and call the fire service first.
- The controller serial number (VS-EMS-…) is on the label of the controller and on the access sheet that came with the cabinet. The app shows it on the station page.
- A photo of the alarm screen saves a round of questions.
- Customers with an app account can also open a ticket from the station page: the station and its log are attached automatically.
Contact support.
In the app
Customers open a support ticket inside the app. We see the station and its log, so you do not need to explain the setup.
By email
info@starkonex.com for questions before you buy and for partners.
Security
Report a vulnerability to security@starkonex.com.