The same controller covers each case. What changes is the set of functions and the limits drawn on your single-line diagram.

By the problem you need to solve.

Pick a case to see what the EMS does about it. The curves show an illustrative day.

Solar with zero export

All editions
00:0006:0012:0018:0024:00Into the battery, not curtailedPlant load
The problem

The operator forbids feeding into the grid, so solar is curtailed whenever the plant uses less.

What the EMS does

The battery takes the surplus instead of curtailing it, and gives it back in the evening.

Self-consumptionZero export per phaseSolar curtailment

Connection limit and peaks

All editions
00:0006:0012:0018:0024:00Incomer limitPeaks covered by the battery
The problem

Short peaks exceed the contracted capacity or trigger penalties.

What the EMS does

The battery covers every peak above the limit of each incomer, so the grid sees a flat line.

Peak shavingImport limit per incomer

Day-ahead price arbitrage

Cloud on Light and Standard
00:0006:0012:0018:0024:00DischargeChargePrice
The problem

Electricity is bought by the hour on the day-ahead market.

What the EMS does

The controller plans charge and discharge from tomorrow’s prices and its own load forecast.

ArbitrageLoad forecastNext-day plan

Backup and blackouts

Standard and Max
00:0006:0012:0018:0024:00From the gridBattery and solarGrid lost
The problem

Grid outages stop production lines.

What the EMS does

The site switches to battery and solar and keeps running. Generators join when the battery runs low.

Island modeBlackout reserveGenerators

Several incomers

All editions
Incomer 1Incomer 2Incomer 3Each incomer’s own limit
The problem

Two or three incomers, transformers and bus ties, each with its own limit.

What the EMS does

One controller keeps every incomer within its own limits, also when a bus tie closes.

Limits per incomerFunctions per incomerBus tie aware

EV chargers and heat pumps

Standard and Max
00:0006:0012:0018:0024:00Incomer limitEV chargers and heat pumpsPlant
The problem

New loads would exceed the connection and need an expensive upgrade.

What the EMS does

Chargers and heat pumps fill the free capacity, run on solar surplus and never push the incomer over its limit.

Load controlIf-then rules

Which edition fits your site?

Answer three questions. The answer updates as you click.

1What should the EMS do?Pick all that apply.
2Where should the history and the app live?
3How big is the site?
Your edition
Light
  • Every edition controls the site locally.
Request a quote for Light

Example sites.

Both run as live demos with simulated data, so you can open the app and look around.

Single-line diagram of an industrial park with three incomers in the Starkonex app

Industrial park, three incomers, 27 battery cabinets

Three incomers with their own limits, a 1600 kVA transformer and a bus tie.

  • Arbitrage on one incomer, self-consumption on the others
  • Solar on two bus sections, EV chargers and a diesel generator
  • Every incomer kept within its own limit
Open in live demo
Plant lit during a grid blackout while the neighbours are dark

Plant with solar, zero export and backup

Rooftop solar behind a zero-export rule, battery storage with a blackout reserve and island mode.

  • Solar surplus stored instead of curtailed
  • Reserve kept for outages
  • Island mode when the grid goes down
Open in live demo

Not sure which case is yours? Send us the diagram.